      Picture Part Name/Part Number Size/Frequency Features / applications Specifications
      Network Transformer
      Network Transformer
      -------------------------------------
      LFS41SADF

      --------------------

      Turns Ratio: PRI/SEC 1CT:1CT ±5%
      Isolation Voltage: 1500 Vrms (Input to Output) 3S
      OCL: 350uH Minimum @100KHz 100mV 8mADC
      LL: 0.40uH Maximum @100KHz 100mV
      CW/W: 20pF Maximum @100KHz 100mV
      DCR: 1.2 Ohms Maximum
      Insertion Loss: -1.10dB Maximum @1MHz ~ 100MHz
      Return Loss: -16dB Minimum @30MHz / -14dB Minimum @40MHz
      -13.5dB Minimum @50MHz / -13dB Minimum @60MHz
      -12dB Minimum @80MHz
      Crosstalk: -45dB Min @0.3~60MHz / -35dB Min @60~100MHz
      Differential to Common Mode Rejection:
      -40dB Min @30MHz / -30dB Min @60MHz / -25dB Min @100MHz
      Operating temperature range: -40°C to +85°C

      Network Transformer
      Network Transformer
      Network Transformer
      -------------------------------------
      LFS1607ADF

      --------------------

      Turns Ratio: PRI/SEC 1CT: 1CT ±5%
      Isolation Voltage: 1500 Vrms 3sec (input to Output)
      OCL: 350uH Minimum @100KHZ 100mv 8mADC Bias
      Leakage Inductance: 0.5uH Maximum @100KHZ 100mV PRI Shorted
      PRI/SEC CW/W: 50pF Typical @100KHZ 100mv
      DCR:1.20 Ohms Max
      Insertion Loss: -18dB Minimum @1MHz-30MHz
      -15dB Minimum @40MHz-50MHz
      -12dB Minimum @60MHz-80MHz
      CMRR: -40dB Minimum @100KHz -100MHz
      Crosstalk: -32 dB Minimum @100KHz -100MHz
      Operating temperature range: 0°C to +70°C

      Network Transformer
      Network Transformer
      Network Transformer
      -------------------------------------
      LGS2417ADF

      --------------------

      Turns Ratio: PRI/SEC 1CT: 1CT ±5%
      Isolation Voltage: 1500 Vrms 3sec (input to Output)
      OCL: 350uH Minimum @100KHZ 100mv 8mADC Bias
      Leakage Inductance: 0.5uH Maximum @100KHZ 100mV PRI Shorted
      PRI/SEC CW/W: 50pF Typical @100KHZ 100mv
      DCR:1.20 Ohms Max
      Insertion Loss: -1.0dB Maximum @100KHz-100MHz
      Return Loss:-18dB Minimum @1MHz-30MHz
      -15dB Minimum @40MHz-50MHz
      -12dB Minimum @60MHz-80MHz
      CMRR: -40dB Typical @100KHz -100MHz
      Crosstalk: -32 dB Minimum @100KHz -100MHz

      Operating temperature range: 0°C to +70°C

      Network Transformer
      Network Transformer
      Network Transformer
      -------------------------------------
      LPS4802AEY

      --------------------

      Turns Ratio: PRI/SEC 1CT:1CT ±5%
      Isolation Voltage: 1500 Vrms (Input to Output)
      OCL: 350uH Minimum @100KHz 100mV 8mADC
      DCR:1.20 Ohms MAX
      LK(100KHZ,100mV):0.5uH MAX
      Insertion Loss: -1.0dB Maximum @100KHz - 100MHz
      Return Loss: -18dB Minimum @1MHz-30MHz
      -14dB Minimum @40MHz
      -13dB Minimum @50MHz
      -12dB Minimum @60MHz-80MHz
      -10dB Minimum @100MHz
      Crosstalk: - 40dB Min @30MHz / -33dB Min @60MHz / - 28dB Min @100MHz
      Differential to Common Mode Rejection:
      -43dB Min @30MHz / -37dB Min @60MHz / -33dB Min @ 100MHz
      Operating temperature range: 0℃ to +70℃

      Network Transformer
      Network Transformer
      Network Transformer
      -------------------------------------
      LGS5001AGY

      --------------------

      Turns Ratio: PRI/SEC TX 1CT: 1CT ±3% RX 1CT: 1CT ± 3%
      Isolation Voltage: 1500 Vrms (Input to Output)
      OCL: 350uH Minimum @100KHz 100mV 8mADC
      Leakage Inductance: 0.4uH Maximum @100KHz 100mv PRI Shorted
      PRI/SEC Cw/w: 20pF Typical @100KHZ 100mV
      Insertion Loss: -1.2dB Maximum @100KHz -100MHz
      -2.0db Maximum @ 125MHz
      Return Loss: -18db Min @1MHz-30MHz/-12dB Min @60MHz
      -12dB Min @80MHz/-10dB Min @100MHz
      Cross Talk: -43dB Minimum @30MHz/-37dB Minimum @60MHz
      -33db Minimum @100MHz
      Rise Time: 2.5ns Typical

      Network Transformer
      Network Transformer
      Network Transformer
      -------------------------------------
      LGS4801AEY

      --------------------

      Turns Ratio: PRI/SEC 1CT:1CT ±5%
      Isolation Voltage: 1500 Vrms (Input to Output)
      OCL: 350uH Minimum @100KHz 100mV 8mADC
      DCR:1.20 Ohms MAX
      LK(100KHZ,100mV):0.5uH MAX
      Insertion Loss: -1.0dB Maximum @100KHz - 100MHz
      Return Loss: -18dB Minimum @1MHz-30MHz
      -14dB Minimum @40MHz
      -13dB Minimum @50MHz
      -12dB Minimum @60MHz-80MHz
      -10dB Minimum @100MHz
      Crosstalk: - 40dB Min @30MHz / -33dB Min @60MHz / - 28dB Min @100MHz
      Differential to Common Mode Rejection:
      -43dB Min @30MHz / -37dB Min @60MHz / -33dB Min @ 100MHz
      Operating temperature range: 0℃ to +70℃

      Network Transformer
      Network Transformer
      Network Transformer
      -------------------------------------
      LGS2401AGF

      --------------------

      Turns Ratio: PRI/SEC 1CT: 1CT ±5%
      Isolation Voltage: 1500 Vrms 3sec (input to Output)
      OCL: 350uH Minimum @100KHZ 100mv 8mADC
      LL: 0.40uH Maximum @100KHz 100mV
      CW/W: 35pF Typical @100KHZ 100mv
      DCR:1.30 Ohms Max
      Insertion Loss: -1.1dB Maximum @1MHz-100MHz
      Return Loss:-16dB Minimum @30MHz / -14dB Minimum @40MHz
      -13.5dB Minimum @50MHz / -13dB Minimum @60MHz
      -12dB Minimum @80MHz
      Crosstalk: -45 dB Minimum @0.3 -100MHz / -35dB Minimum @60-100MHz
      Differential to Common Mode Rejection:
      -40dB Min @30MHz / -30dB Min @60MHz / -25dB Min @100MHz
      Operating temperature range: -40°C to +85°C

      Network Transformer
      Network Transformer
      Network Transformer
      -------------------------------------
      LGS2401ADF

      --------------------

      Turns Ratio: PRI/SEC 1CT: 1CT ±5%
      Isolation Voltage: 1500 Vrms 3sec (input to Output)
      OCL: 350uH Minimum @100KHZ 100mv 8mADC Bias
      Leakage Inductance: 0.5uH Maximum @100KHZ 100mV PRI Shorted
      PRI/SEC CW/W: 50pF Typical @100KHZ 100mv
      DCR:1.40 Ohms Max
      Insertion Loss: -1.0dB Maximum @100KHz-100MHz
      Return Loss:-18dB Minimum @1MHz-30MHz
      -15dB Minimum @40MHz-50MHz
      -12dB Minimum @60MHz-80MHz
      CMRR: -40dB Typical @100KHz -100MHz
      Crosstalk: -32 dB Minimum @100KHz -100MHz
      Operating temperature range: 0°C to +70°C

      Network Transformer
      Network Transformer
      Network Transformer
      -------------------------------------
      LFS1606ADF

      --------------------

      Turns Ratio: PRI/SEC 3CT: 10CT ±5%
      Isolation Voltage: 500 Vrms (Input to Output) 60s
      OCL: 1. 5uH Minimum @1KHz 1V(P1-3, P6-8)
      OCL: 11. 5uH Minimum @1KHz 1V(P16-14, P11-9)
      CW/W: 10pF Maximum @100KHz 100mv
      DCR: 0.8 Ohms Maximum
      LL: 0.8uH Maximum @100KHZz100mv